Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Med Arch ; 77(2): 137-141, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37260807

RESUMO

Background: Congenital fibrosis of extraocular muscles ( CFEOM) is a group of genetically defined eye-moving disorders. The syndrome is clinically characterized by congenital non-progressive ophthalmoplegia caused by dysinervation of the cranial nerves with or without ptosis. As a main sign of a CFEOM, extraocular muscles get shrunken and fibrotic, which makes surgery more technically demanding and the result more unpredictable, which makes the treatment challenging and highly customized. Our paper presents variations of the clinical picture and treatment cases of CFEOM1. Objective: To outline the importance of the clinical examination with the exact measurement of deviations for the patients with ocular fibrosis and passive duction test under general anesthesia, establishing them as the main criteria for treatment. Methods: We treated seven patients (14 eyes) with CFEOM1. The decision of the treatment was based on the measurement of the eye position in the primary position (PP), the severity of compensatory head position (CHP), restriction of motility, and passive motility test performed before surgery in general anesthesia. In 3 cases, patients were treated conservatively with the treatment of refractive error and amblyopia. However, in 4 patients, CHP and position of the eyes in PP were not acceptable, motility was severely impaired, and patients underwent surgery. The first surgery was performed on eye muscles: recession of inferior rectus muscle (IRM), anteposition, and resection of superior rectus muscle (SRM). As a second step procedure, ptosis surgery was performed. When the muscle was too tight, and it wasn't possible to have a satisfying result with conventional surgery, we used a tissue expander to improve the position and motility of the affected eyes. Results: In all operated cases, CHP has significantly improved and the position of the eyes in PP. Conclusion: Exact eye and head position measurements and a passive motility test during general anesthesia should guide the surgery. In the case when conventional surgery is not possible, implantation of a bovine pericard is a safe and effective method.


Assuntos
Transtornos da Motilidade Ocular , Oftalmoplegia , Humanos , Animais , Bovinos , Músculos Oculomotores/cirurgia , Transtornos da Motilidade Ocular/etiologia , Transtornos da Motilidade Ocular/terapia , Transtornos da Motilidade Ocular/patologia , Fibrose , Oftalmoplegia/etiologia , Oftalmoplegia/terapia , Oftalmoplegia/patologia
2.
Mater Sociomed ; 35(1): 73-78, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37095881

RESUMO

Background: Corneal ectasia is a sight-threatening complication of corneal refractive surgery characterized by progressive steepening and thinning of the cornea and subsequent loss of best-corrected visual acuity. Objective: To report the clinical outcomes following treatment of post-laser in situ keratomileusis (LASIK) induced ectasia. Methods: This is a retrospective case series of 7 patients (10 eyes) which developed post-LASIK ectasia. In these cases of postoperative ectasia, the presented clinical signs were either forme fruste keratoconus, thin cornea, posterior elevation map value > +15.0µm, or residual stromal bed < 300µm. All cases were treated with either collagen crosslinking (CXL) alone or combined with PRK or CXL and phakic intraocular implant using the Dresden protocol and a slight modification thereof. In all cases, the flap was created using the Moria M2 mechanical microkeratome (average flap thickness 118.15±12.88µm), and refractive error was corrected using the Wavelight Allegretto excimer laser. Results: Average preoperative corrected visual acuity (CDVA) was 0.75 (±0.26) Snellen. Postoperative CDVA significantly increased to 0.86 (±0.13) Snellen (p=0.04, paired t-test). One eye lost three lines of its baseline CDVA (before ectasia), while all other eyes regained lines of CDVA. All cases remained stable during the follow-up. Conclusion: Several surgical procedures are used for the management of corneal ectasia. However, the best surgical approach should be determined based on the state of progression of the disease. Although ectasia remains a potentially devastating complication after refractive surgery, most patients can regain functional visual acuity with appropriate management, and corneal transplantation is infrequently indicated.

3.
Acta Inform Med ; 31(1): 62-67, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37038487

RESUMO

Background: Among various visual functions, stereoacuity, or the ability to perceive depth, is the most sophisticated binocular function. Many publications discuss the influence of retinal image formation by multifocal intraocular lenses on glare and contrast sensitivity, but only a few present results of testing binocular vision in patients with multifocal intraocular lenses. Objective: This article is designed to review the results of testing binocular vision in patients with multifocal intraocular lenses implanted in cataract surgery. Methods: This article was performed based on a literature review and Internet search through scientific databases such as PubMed, Scopus, Web of Science, and Google Scholar. Results: Some reports found that patients implanted with the monofocal lens, when measured with a near addition, presented statistically significant better stereoacuity scores than those implanted with any of the multifocal intraocular lens types. When the TNO test was used for measurement, statistically significant better stereoacuity was disclosed with the refractive multifocal intraocular lens than with the diffractive-based multifocal intraocular lens design. Stereoacuity scores, even within the same types of lenses, were significantly better with the Titmus test than with the TNO test. Conclusion: Stereoacuity is not affected by multifocality-induced retinal blur as it is by other causes of image degradation such as small residual refractive error very early opacification of ocular media or dry eye. Multifocal intraocular lenses do not cause more functional aniseikonia than would be expected with a monofocal intraocular lens. Since stereoacuity is compromised with unilateral multifocal intraocular lens implantation bilateral implantation should be attempted.

4.
J. optom. (Internet) ; 13(1): 59-68, ene.-mar. 2020. tab, graf
Artigo em Inglês | IBECS | ID: ibc-195309

RESUMO

PURPOSE: To determine the significance of changes and and inter-relationships between three markers of binocular function (aniseikonia, distance and near stereoacuity) following unremarkable LASIK at 3 and 6 months postoperatively. METHODS: All patients underwent LASIK using the Schwind Amaris 750S and the flaps were created using Intralase 150 kHz. Patients were I, monocular myopes II, binocular myopes III, binocular hyperopes IV, binocular astigmats V, anisometropes and VI, matched age and gender control (n = 20 in each group except III where n = 18). Aniseikonia (Awaya test), distance and near stereoacuity (Randot tests) were measured before surgery, and at 3 and 6 months after surgery. At all times data were collected under constant conditions and analyzed using appropriate non-parametric statistical tests. RESULTS: The following statistically significant changes were found after applying the Bonferroni correction (p ≤ 0.001); aniseikonia reduced (groups I, III, IV, V), stereoacuity improved at distance (groups I, III-V) and near (groups I, V). Inter-group differences in aniseikonia distance and near stereoacuity were significant preoperatively, but not postoperatively. In groups I, IV and V, the changes in aniseikonia and stereoacuity (near and distance) were significantly correlated with the preoperative value. Aniseikonia was significantly correlated with distance and near stereoacuity preoperatively but not postoperatively. CONCLUSION: Binocular function improved in all groups after LASIK except in binocular myopes. In general, binocular function was still low compared with the control group at six months postoperatively. It is unclear why binocular function improved in the binocular astigmats


OBJETIVO: Determinar la significancia de cualquier cambio, así como las interrelaciones entre tres marcadores de la función binocular (aniseiconía, estereoagudeza de lejos y de cerca) tras LASIK sin complicaciones a los 3 y 6 meses postoperatorios. MÉTODOS: A todos los pacientes se les realizó cirugía LASIK con el laser Schwind Amaris 750S, creándose los flaps con Intralase 150 kHz. Los grupos de pacientes fueron: I miopes monoculares, II miopes binoculares, III hipermétropes binoculares, IV astígmatas binoculares, V anisométropes y VI controles equivalentes en edad y género (n = 20 en cada grupo, exceptuando III donde n = 18). Se midió la aniseiconía (prueba de Awaya), la estereoagudeza de lejos y de cerca (pruebas Randot) durante el preoperatorio, y a los 3 y 6 meses posteriores a la cirugía. En todo momento se recabaron los datos en condiciones constantes, analizándose los mismos con pruebas estadísticas no paramétricas adecuadas. RESULTADOS: Se encontraron los siguientes cambios estadísticamente significativos tras aplicar la corrección de Bonferroni (p ≤ 0,001); se redujo la aniseiconía (grupos I, III, IV, V), y mejoró la estereoagudeza de lejos (grupos I, III-V) y de cerca (grupos I, V). Las diferencias inter-grupo en cuanto a aniseiconía de lejos y de cerca y la estereoagudeza de cerca fueron significativas en el preoperatorio, pero no en el postoperatorio. En los grupos I, IV y V, los cambios en cuanto a aniseiconía y estereoagudeza (de cerca y de lejos) guardaron una correlación significativa con el valor preoperatorio. La aniseiconía guardó una correlación significativa con la estereoagudeza de lejos y de cerca en el preoperatorio, pero no el postoperatorio. CONCLUSIÓN: La función binocular mejoró en todos los grupos tras la cirugía LASIK, excepto en la miopía binocular. En general, la función binocular fue aún baja al compararse con el grupo control a los seis meses postoperatorios. No queda claro por qué la función binocular mejoró en el astigmatismo binocular


Assuntos
Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Aniseiconia/fisiopatologia , Astigmatismo/cirurgia , Percepção de Profundidade/fisiologia , Hiperopia/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Astigmatismo/fisiopatologia , Hiperopia/fisiopatologia , Miopia/fisiopatologia , Estudos Prospectivos , Visão Binocular/fisiologia , Acuidade Visual/fisiologia
5.
J Optom ; 13(1): 59-68, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31668775

RESUMO

PURPOSE: To determine the significance of changes and and inter-relationships between three markers of binocular function (aniseikonia, distance and near stereoacuity) following unremarkable LASIK at 3 and 6 months postoperatively. METHODS: All patients underwent LASIK using the Schwind Amaris 750S and the flaps were created using Intralase 150 kHz. Patients were I, monocular myopes II, binocular myopes III, binocular hyperopes IV, binocular astigmats V, anisometropes and VI, matched age and gender control (n = 20 in each group except III where n = 18). Aniseikonia (Awaya test), distance and near stereoacuity (Randot tests) were measured before surgery, and at 3 and 6 months after surgery. At all times data were collected under constant conditions and analyzed using appropriate non-parametric statistical tests. RESULTS: The following statistically significant changes were found after applying the Bonferroni correction (p ≤ 0.001); aniseikonia reduced (groups I, III, IV, V), stereoacuity improved at distance (groups I, III-V) and near (groups I, V). Inter-group differences in aniseikonia distance and near stereoacuity were significant preoperatively, but not postoperatively. In groups I, IV and V, the changes in aniseikonia and stereoacuity (near and distance) were significantly correlated with the preoperative value. Aniseikonia was significantly correlated with distance and near stereoacuity preoperatively but not postoperatively. CONCLUSION: Binocular function improved in all groups after LASIK except in binocular myopes. In general, binocular function was still low compared with the control group at six months postoperatively. It is unclear why binocular function improved in the binocular astigmats.


Assuntos
Aniseiconia/fisiopatologia , Astigmatismo/cirurgia , Percepção de Profundidade/fisiologia , Hiperopia/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Adulto , Astigmatismo/fisiopatologia , Feminino , Humanos , Hiperopia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Estudos Prospectivos , Visão Binocular/fisiologia , Acuidade Visual/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...